nwbc links
I have a question regarding the links within NWBC URL. is it possible to extract every link as a URL ? I know its possible to extract a URL for the work centers but how do i extract the links within...
View ArticleGRC work inbox icon not automatically refreshed
Dear GRC experts, I have installed GRC 10, SP level 11 on NW EHP2 (SP level 12). I am wondering if anybody of you has encountered the following error: When the user who received AC work item logon to...
View ArticleHi everybody,
My query is that if I open a particular "Subprocess/Control" [(i.e., from Master Data -->Org --> Org --> Subprocess/Control) in SAP GRC 10.0] its showing a lot of Tabs while if I open the same...
View ArticleSetting Sequence for Actions within a Request type
Hello everyone, We are exploring an opportunity to set the sequence for the standard actions within a custom request type. We plan to execute the following sequence of actions within a SAME request...
View ArticleGRC AC 10.0: PFCG Authorisation Sync Fail - Please Help :)
Hello everyone, We have GRC AC 10.0 installed with ECC 6.0 backend (SAP_BASIS 702 006 SAPKB70206). I have an error as follows: The RFC connector has been created and tested, with the connection...
View ArticleRe: Errors while running Sync Jobs in GRC 10
Hi Raj, I have a similar error for which I have put up a separate post, your input would be highly valuable. My RFC connection works via the test in SM59 but when executing GRAC_AUTH_SYNC I get a...
View ArticleRe: 'Approve' button not displaying in the Approve Role screen Inbox - AC 10
Hi John, I am also facing the same issue "when I try to activate the MSMP, i get a warning with the message - "no data is maintained in table GRFNMWCNGLBESR for process SAP_GRAC_ROLE_APPR". Role...
View ArticleRe: GRC 10 - Risk Analysis in legacy system
Hi Claudio Ekel Can you share some inputs on the Legacy Risk Analysis.We have configured the Legacy Connector as per the note 1594963 ; Placed the files on the server & tried running...
View ArticleRe: GRC PC - Sign off error on GRPC_SAP_JOB_AFTER_SIGNOFF
Hello Jose, Kindly check the control is available in the system or not and also check the validity of that control (if available). May be thats why you are getting error. Thanks, Ranveer
View ArticleRe: GRC AC 10.0: PFCG Authorisation Sync Fail - Please Help :)
Can you check the entries in the table GRFNCONNSCNLK and see if they are populated to the correct Integration Scenario. Also check if the Maintain Connector settings is mainatined Mohammed
View ArticleRe: Offline Risk Analysis: GRC10 - Legacy system
Hi Japneet, Thanks for the inputs. Please check my response below: 1. I Ran the Batch Risk Analysis. But in first place , i dont see the legacy users and roles after running the Repository &...
View ArticleRe: nwbc links
Hi Rahul The NWBC Workcenter information is defined in the launchpad definitions. The webdynpro is listed as the application To try to obtain the full URL you would need to extract a few tables and...
View ArticleRe: GRC AC 10.0: PFCG Authorisation Sync Fail - Please Help :)
Hi Paul For your connectors you need to: Create the RFC Connection in SM59 and test that it worksCreate a Logical System for the Connector in transaction BD54 (same value as your connector)Complete the...
View ArticleRe: Setting Sequence for Actions within a Request type
HI Mayuresh It doesn't look like you can based on table GRACREQTYPACT as the table does not contain a sort key fort eh sequencing
View ArticleRe: GRC work inbox icon not automatically refreshed
HI Ivana This is POWL functionality but you can set the automatic refresh via IMG Governance, Risk and Compliance > General Settings > POWL for Work Inbox > Define QueryLocate GRFN_INBOX_AC...
View ArticleRe: 'Approve' button not displaying in the Approve Role screen Inbox - AC 10
HI Sasi this is a warning message only Table GRFNMWCNGLBESR is the Escape Condition configuration you can do in Step 1 For role approval, you can create an escape condition if the Approver is not...
View ArticleRe: GRC AC 10.0: PFCG Authorisation Sync Fail - Please Help :)
Hi Colleen, Many thanks for taking the time to respond to my query - greatly appreciate it. 1. I have created a connector in SM59 and tested it. It works. 2. I am on BD54 BUT I don't understand what...
View ArticleRe: GRC PC - Sign off error on GRPC_SAP_JOB_AFTER_SIGNOFF
Hello Ranveer The control doesn't exists. It seems that has been manually deleted.I think that when the job is trying to find that control, it fails. Any ideas? Thank you,
View ArticleRe: GRC AC 10.0: PFCG Authorisation Sync Fail - Please Help :)
I think I'm getting there....I've got a new error : Program for Authorisation data synchronisation: "Unable to locate connector RFCCon1PFCG authorisation sync failed with errors" Brilliant stuff!...
View ArticleGRC AC 10 - BRM Error when deleting role
Turns out it was part of the existing request. Thanks for your help.
View Article